![thermo king spectrum sb gfci reset thermo king spectrum sb gfci reset](https://i.ytimg.com/vi/xfO62rmnbQQ/sddefault.jpg)
- #THERMO KING SPECTRUM SB GFCI RESET HOW TO#
- #THERMO KING SPECTRUM SB GFCI RESET MANUAL#
- #THERMO KING SPECTRUM SB GFCI RESET CODE#
#THERMO KING SPECTRUM SB GFCI RESET MANUAL#
This manual is published for informational purposes only and the information so provided should not be considered as all-inclusive or covering all contingencies. The information in this manual is provided to assist owners, operators and service people in the proper upkeep and maintenance of Thermo King units. What is the purpose of the Thermo King maintenance manual? If unit/zone is shut down repair immediately. If the unit still won’t start, then verify voltage to the HPCO switch. Check the wiring harness on the 8D circuit. If the unit starts, then the HPCO switch is defective. Disconnect the harness and bypass the HPCO switch. The HPCO is located on the top of the compressor. Check for a defective high-pressure cutout (HPCO) switch.Ĭheck for a defective high-pressure cutout (HPCO) switch. Warning: Any attempt to jump start the battery may cause it to explode. If the starter fails to engage and the voltage falls to 1V or 0V, then you have a bad battery. Jump the starter and observe the battery voltage. Where is the HPCO switch on a Thermo King?Ĭheck for a defective high-pressure cutout (HPCO) switch. Check for a defective high-pressure cutout (HPCO) switch.
![thermo king spectrum sb gfci reset thermo king spectrum sb gfci reset](https://i.ebayimg.com/thumbs/images/g/OuAAAOSwtRJg6Lx7/s-l300.jpg)
What to do if your Thermo King battery goes bad? Minus a few exceptions, you likely have a fuel system problem. This is one of the most common alarm codes you will encounter.
![thermo king spectrum sb gfci reset thermo king spectrum sb gfci reset](https://i3.ytimg.com/vi/56ylbw03bjk/hqdefault.jpg)
Trace the wiring circuit and check any fuses or switches connected to the circuit. You will need a wiring schematic for the Thermo King unit you are working on.
#THERMO KING SPECTRUM SB GFCI RESET HOW TO#
How to troubleshoot alarm codes 10 and 20 on a Thermo King?ĭo a voltage drop test to check for an open circuit. What happens if you jump start a Thermo King? If it won’t clear: For guarded access scroll to ddr45 press TK and clear.
![thermo king spectrum sb gfci reset thermo king spectrum sb gfci reset](https://i.ytimg.com/vi/vnL4XgJKCK8/maxresdefault.jpg)
SB/Spectrum, cycles to off hold TK and clear buttons down. Scroll thru when you see 71 press enter to clear. Scroll thru, you should see hour meter limit and actual hours use the arrow keys to wind back hourmeter to 1.
#THERMO KING SPECTRUM SB GFCI RESET CODE#
How to reset the code 71 for a ThermoKing? If this is true your battery may be starting to fail. Check the amp meter in your gauge menu if it is above 5 amps the unit will not shut off. Why does my Thermo King Battery not cycle?Īnswer: The most common cause for a unit not to cycle has to do with charging.